At Part Orbit, we can help you procure top NSN parts such as Transformer Power with competitive prices and rapid lead-times. This particular item was manufactured by Technitrol Inc and is listed alongside the part number 006137. With current availability for this part, we invite you to begin with a personalized quote that you may receive through the submission of an RFQ form as provided below. When completing our form for 006137 part, we ask that you offer us as many details as possible so that our team members may craft a solution that serves to accommodate your individual needs and requirements. With team members available for customers at all times, feel free to submit requests as needed and a dedicated account manager will reach out to you in just 15 minutes or less.Beyond Technitrol Inc parts such as Transformer Power, we carry many other NSN parts and components that cater to a diverse set of industries and applications. National Stock Numbers, commonly referred to as NSNs, are 13-digit numerical codes that serve to efficiently categorize ‘standardized material items of supply’ for easier trade. NSNs are recognized by all NATO countries, and their codes may be split up into separate groups that determine the country that first codified the item, the group and class that the item belongs to, and a unique string that represents the item itself. Get started on the purchasing process today and see how Part Orbit can fulfill all your operational needs with ease.
Specifications
Description
Request a Quote
Get pricing for 006137
NSN Information for Part Number 006137 with NSN 5950-01-120-8831, 5950011208831
Characteristics Data of NSN 5950-01-120-8831, 5950011208831
| MRC | Criteria | Characteristic |
|---|---|---|
| AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
| ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 3.812 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 3.593 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| ACZB | FREQUENCY RATING | 400.0 HERTZ NOMINAL SINGLE COMPONENT |
| ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | THREE PHASE TO SINGLE PHASE SINGLE COMPONENT AND THREE PHASE TO THREE PHASE SINGLE COMPONENT |
| ACZD | TRANSFORMER WINDING CONNECTION TYPE | DELTA-DELTA AND DELTA-WYE |
| ACZF | MAXIMUM TRANSFORMER POWER RATING | 950.0 VOLT-AMPERE SINGLE COMPONENT |
| ADAQ | BODY LENGTH | 6.281 INCHES MAXIMUM |
| ADAT | BODY WIDTH | 5.187 INCHES MAXIMUM |
| ADAU | BODY HEIGHT | 3.250 INCHES MAXIMUM |
| AEHZ | MAXIMUM OPERATING TEMP | 170.0 DEG CELSIUS |
| AKNA | INCLOSURE TYPE | FULLY INCLOSED |
| AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
| AXGY | MOUNTING METHOD | THREADED HOLE SINGLE GROUP |
| BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 8 SECONDARY SINGLE COMPONENT |
| CQJX | NOMINAL THREAD SIZE | 0.312 INCHES SINGLE GROUP |
| CWJS | WINDING OPERATING VOLTAGE | 115.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
| CWJS | WINDING OPERATING VOLTAGE | 24.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY |
| CWJS | WINDING OPERATING VOLTAGE | 24.00 AC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY |
| CWJS | WINDING OPERATING VOLTAGE | 7.80 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY |
| CWJS | WINDING OPERATING VOLTAGE | 8.80 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY |
| FEAT | SPECIAL FEATURES | 1 PRIMARY WINDING; 8 SECONDARY WINDINGS |
| THSD | THREAD SERIES DESIGNATOR | UNC SINGLE GROUP |
| TTQY | TERMINAL TYPE AND QUANTITY | 35 TAB, SOLDER LUG |