If you are interested in NSN 5925-01-050-9030 with the part number 214-0006-009, we have you covered at Part Orbit. This particular item is described as a Circuit Breaker, and it was manufactured by Rockwell Collins Inc. If you would like to purchase this particular part number, or any other NSN part on our website, first begin with a competitive quote which you may receive through the submission of an RFQ form for 214-0006-009 part as provided below. With team members readily available for customers 24/7x365, responses to quote requests will be given in as little as 15 minutes or less.
Whether you want NSN 5925-01-050-9030 produced under the CAGE Code 95105 or other Rockwell Collins Inc parts, we are unmatched in our availability and quality. With our NO CHINA SOURCING pledge, we ensure that all offered NSN parts have come from leading global manufacturers that we trust and have undergone all necessary quality assurance measures. National Stock Numbers, or NSNs, are 13-digit numerical codes that serve to classify all ‘standardized material items of supply’. The NSN system is practiced by all NATO countries, facilitating an ease of trade. As a leading distributor of NSN parts, we invite you to take advantage of our services today and see how we can serve as your strategic sourcing partner.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5925-01-050-9030 Item Description: Circuit Breaker | 5925 | 010509030 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
214-0006-009 | 5 | 1 | C | A |
MRC | Criteria | Characteristic |
---|---|---|
TTQY | Terminal Type And Quantity | 3 COMPRESSION |
CPLM | Maximum Continuous Load Current Rating Per Pole | 50.0 AMPERES AC ALL LOCATIONS |
AFJN | Fragility Factor | MODERATELY RUGGED |
BBRG | Storage Type | GENERAL PURPOSE WAREHOUSE |
CPRG | Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 10000.0 AC ALL LOCATIONS |
FREQ | Frequency In Hertz | 60.0 ALL LOCATIONS |
CPRH | Circuit Protection Type | OVERCURRENT ALL LOCATIONS |
CPRL | Trip Release Characteristic | TIME DELAY ALL LOCATIONS |
CPRJ | Trip Release Method | THERMAL-MAGNETIC ALL LOCATIONS |
AJEC | Boss Height | 0.250 INCHES NOMINAL |
AKPX | Pole Quantity | 3 |
MRC | Decoded Requirement | Clear Text Reply |
AXHR | Mounting Facility Type And Quantity | 6 TERMINAL |
CPRQ | Reset Method | MANUAL |
CRCF | Trip Release Ambient Temp Rating | 40.0 DEG CELSIUS NOMINAL ALL LOCATIONS |
CPRR | Main Contact Tripping Mechanism Type | TRIP FREE |
CPRW | Actuator Function | TRIP-RESET |
ADAT | Body Width | 2.230 INCHES NOMINAL |
CPRT | Manual Actuator Type And Quantity | 1 TOGGLE |
ADTV | Case Material | PLASTIC |
TTQY | Terminal Type And Quantity | 3 CLIP AND |
ADAQ | Body Length | 6.250 INCHES NOMINAL |
ADAU | Body Height | 2.580 INCHES NOMINAL |
AEBQ | Center To Center Distance Between Terminals Parallel To Width | 0.740 INCHES NOMINAL |
AAQL | Body Style | MULTIPOLE-SINGLE ACTUATOR TYPE |
CPRF | Operating Voltage Type And Rating Per Pole In Volts | 240.0 AC ALL LOCATIONS |
APNQ | Arc Quenching Method | MAGNETIC BLOWOUT |
CQWN | Trip Delay Time In Seconds Per Rated Continuous Current | 240.000 MAXIMUM AT 200 PCT ALL LOCATIONS |
CPRN | Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent | 125.0 ALL LOCATIONS |
CPRX | Actuator Position Designation | AT POLE TWO |
CQXF | Inclosure Protection Type For Which Designed | FUNGUS RESISTANT |
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”. |
We Hope that You Will Visit Us Again the Next Time You Need NSN Parts and Make Us Your Strategic Purchasing Partner.
Request for Quote